  
 X1200M eXcelon Gouriki Mono Digital Power Amplifier
| The Japanese kanji characters symbolize “powerfulness”. It is a character that stands for rigidity and strength. The X1200M delivers the highest levels of output power possible thanks to its Dual Power Supply that reduces voltage loss allowing the amplifier to perform under extreme demands. | |
| |
| • | Powerful Amplifier Series | | • | Class D Mono Power Amplifier | | • | Dual Power Supply | | • | Digital Σ Drive | | • | 1Ω Load Capability | | • | Thermal Management | | • | Power MOS-FET Switching Power Supply | | • | Optional Bass Boost Wired Remote (KCA-WR10) | | • | Cast Aluminum Heat Sink Design | | • | Dual Cooling Fans | | • | Double-Sided Glass Epoxy Circuit Boards | | • | Hexagon Screw Type 4AWG Terminal Blocks - Power/Ground | | • | Hexagon Screw Type 8AWG Terminal Blocks – Speaker Output | | • | Single-Side Exposure Of Terminals For Multi-Installation | | • | Line Output Terminals For Extension | | • | 2-Year Warranty | |
| |
| For subwoofer applications, Class D amps are beautifully efficient and their small size offers installation flexibility. Before amplifying an incoming signal, a Class D amp converts the signal to digital. Digital signals can be amplified very efficiently, so you get a lot more power with less current. Less input current reduces power supply size and generates less waste heat, thus reducing the heat sink size. The amp then converts the amplified signal back to analog. | |
| |
| This advanced negative feed back circuit improves damping factor and increases accuracy and sound quality. When a signal is passed to a subwoofer, like a 50Hz note, the speaker will move and create the note. However, because the speaker has mass and a suspension, it won’t stop moving once it’s in motion. This extra movement (sound) creates a type of distortion that’s not part of the original signal. The negative feedback circuit senses this unwanted movement and send out an opposite pulse to stop the speaker like an electronic brake. | |
| |
| This design provides one power supply for positive current and one power supply fro negative current. The result is cleaner voltage source, less failure due to short circuit or power loss due to variances in transformer tolerances, and less transformer noise even when the positive and negative loads are unstable! | |
| |
| The infrasonic filter eliminates inaudible ultra low frequencies that can cause unwanted distortion. The filter can be adjusted between 15Hz to 40Hz depending on the subwoofer and enclosure being used. | |
| |
| The built-in variable LPF allows the user to select a variable frequency and remove damaging high frequencies from the subwoofer pathway for more bass output with less distortion. | |
| |
| This optional KCA-WR10 wired remote allows bass boost frequency adjustments and level adjustments for bass. For example you could add a 8dB boost at 43Hz by simply adjusting the position of the knobs. If you are using two amps, you can use a phone splitter so one bass boost can operate both amps. | |
| |
| RATED OUTPUT POWER (14.4V): | | • | 800W RMS x 1 @ 4Ω | | • | (20Hz-200Hz @ 1%THD) | | • | 1200W RMS x 1 @ 2Ω | | • | (100Hz @ 1% THD) | |
| | RMS POWER OUTPUT (CEA-2006) | | • | 800W RMS x 1 | | • | (RMS @ 4Ω, 1% THD+N) | | • | 75dBa Signal-To-Noise Ratio | |
| | BUILT-IN CROSSOVER CONTROL: | | • | Variable Low-Pass Filter: 50Hz-200Hz (-24dB/oct) | | • | Variable Infrasonic Filter: 15Hz-40Hz (-24dB/oct) | |
| | TERMINALS: | | • | Battery: Hex Type (4 AWG) | | • | Ground: Hex Type (4 AWG) | | • | Speaker: Hex Type (8 AWG) | |
| | • | Operating Voltage: 14.4V | | • | Current Consumption: 90A | | • | S/N Ratio: 105dB | | • | Frequency Response: 20Hz-200Hz | | • | Input Sensitivity: 0.2V ~ 5.0V | |
| | Installation Size: | | • | Width: 14-15/16” (380mm) | | • | Height: 2-5/8” (66mm) | | • | Depth: 11-1/4” (286mm) | | • | Weight: 11.0 lbs. (5Kg) |
|
| Operating Voltage | 14.4V (11V - 16V allowable) | | Current Consumption | 90 A | | Dimensions (W x H x D) | 380 x 66 x 286 mm (14-15/16 x 2-5/8 x 11-1/4) | | Weight | 5.0 kg (11.0 lbs) |
|
| CEA-2006 Standard | 800 W x 1 | | RMS Watts per channel @ 4 ohms, 1% THD+N | | 75 dBA | | Signal to Noise Ratio (Reference: 1 Watt into 4 ohms) |
| | Max Power Output | 2400 W | | Rated Power Output |
| 14.4 V |
|
|
| 800 W x 1 |
|
(4Ω) (20 Hz - 200 Hz, 1.0% THD) |
| 1200 W x 1 |
|
(2Ω) (100 Hz, 1.0% THD) |
| | Frequency Response | 20-200Hz(±1dB) | | Input Sensitivity | 0.2 V - 5.0 V (MIN-MAX) | | Input Impedance | 10 kΩ | | Signal to Noise Ratio | 105 dB | | Low Pass Filter Frequency | | (-12 dB/oct.) | | | | 50 Hz - 200 Hz (variable) | | Low-Pass Filter Frequency |
| | High Pass Filter Frequency | - | | Dimensions (W x H x D) | 380 x 66 x 286 mm (14-15/16 x 2-5/8 x 11-1/4) |
| Download | File Type | Description | Release Date |
|---|
| Download | Owners Manuals | X1200M Owners Manual | Jul 28, 2009 | | Download | Catalogs | 2010 Excelon Product Catalog - Canada | Mar 17, 2010 |
 *Product descriptions, specifications and features are subject to change without notice. For proper fit and compatibility check with your authorized Kenwood dealer.
|
|